22/05/2026
Glory Biomedical Solutions
• Medical Equipment Supply
• Reagent and Accessories Supply
• Equipment Planning
• Equipment Specification
• Vendor Development
• Technical and Cost Comparisons
• Negotiation and Ordering of
Equipment
• Installation and Commissioning
• Maintenance and Repair
For more information, please contact us at
📞+251 92 379 8904
📞+251 95 513 9833
Email:[email protected]
08/05/2026
Mobile OR Light
Brand: Mindray
Model: C7M
Type: Mobile
Contract: 092 379 8904
06/05/2026
At Glory Biomedical Solutions, we provide expert assistance in the following areas: 🏥🔧
• Equipment Planning 📋
• Equipment Specification 📝
• Vendor Development 🤝
• Technical and Cost Comparisons ⚖️
• Negotiation and Ordering of Equipment 💼
• Installation and Commissioning 🛠
• Maintenance and Repair 🔧
For more information, please contact us at
📞092 379 8904
JJU S.H.Yabare Comprehensive Specialized HospitalBlack Lion Esp.HospitalAdama General Hospital & Medical CollegeAdinas General Hospital Bahir DarWAJi Healthcare AMHospitaala Kompireensiivii Ispeeshaalaayizdii Yuunivarsiitii WallaggaaMenelik II referral hospital
06/05/2026
Water distiller 20l/hr
CONTACT: 092 379 8904
04/05/2026
CPAP For Neonatal Patients
The system eliminates the need for multiple separate devices by integrating:
Gas mixing (electronic blending for FiO2)
Humidification (automatic 3-day refill system)
PEEP chamber (innovative one-hand adjustment)
Air compressor (built-in, no external air source needed)
Pulse oximeter (integrated Masimo SET® technology)
Cost Efficiency & Sustainable
User-Friendly Precision
Contact: 0923798904
29/04/2026
🌟 Stock Update! 🌟
We are excited to announce the availability of our latest medical equipment for neonatal care:
👶 INFANT RADIANT WARMER
👉 Model HKN-90
👉 Model HKN-9010
💡 NEONATE BILIRUBIN PHOTOTHERAPY EQUIPMENT
👉 Model XHZ-90L
👉 Model XHZ-90S
🛏 INFANT INCUBATOR, INFANT INCUBATOR WITH PHOTOTHERAPY
👉 Model YP-100B
🔵Other Neonatal Healthcare supportive Equipment
For inquiries, please contact us at
📞 0923798904.
Let’s ensure the best care for our little ones! 💖
Call now to connect with business.
28/03/2026
Stock Available
Mindray Anesthesia Machine
Model: A1
✔️12.1-inch capacitive touchscreen,
configurable screen layouts
✔️Precise and individualized ventilation
✔️Integrated compact breathing
circuit with classic panel design
✔️Compact main unit, Modular and
flexible design
Contact us today
0923798904
0703798904
17/03/2026
Stock update
👉Anesthesia Machine
Model: A1with PCV, VCV, SIMV, CPAP
Model: A3 With PCV, VCV, SIMV, CPAP + CO2
👉Mechanical Ventilator
Model: SV 300 With Adult, Pediatric Accessories
Model: SV 300 With Adult, Pediatric & Neonatal Accessories
👉ECG Machine
Model: R12
👉Patient Monitor
Model: Umec 150
👉Defibrillator
Model: D30
👉Vital sign Monitor
Model: VS 600
👉Operation Room Table (OR Table)
Model: unibase 30
👉Mobile Operation Light
Model: C7M and Hyleed 600M
👉Operation Room Light (ceiling)
Model: C7/C8
👉Infusion Pump (Bensfusion
Model: UVP
📞: 092 379 8904
23/12/2025
Clinical Application of the Mindray SV 300 Ventilator: Optimizing Lung Protection through Mechanical Power Monitoring
The Mindray SV 300 mechanical ventilator integrates advanced lung protection tools directly into clinical workflow, one of the most impactful being its real-time Mechanical Power (MP) monitoring. This feature provides clinicians with a comprehensive, dynamic indicator to assess and minimize ventilator-induced lung injury (VILI) risk during critical care.
Why Mechanical Power Matters
Mechanical Power represents the total energy delivered by the ventilator to the respiratory system per minute. Elevated MP is independently associated with increased mortality and postoperative pulmonary complications. The SV 300 utilizes an integrated algorithm to continuously calculate MP without requiring additional accessories or being limited to specific ventilation modes, offering seamless monitoring in volume or pressure control.
Clinical Implementation
In patients at high risk for lung injury—such as those with ARDS, undergoing major abdominal or thoracic surgery, or with sepsis—the SV 300’s MP value serves as a guide to tailor ventilation settings. Clinicians can adjust tidal volume, driving pressure, PEEP, and respiratory rate to keep MP below the demonstrated threshold of 17 J/min, thereby reducing the cumulative stress on alveoli.
Integration with Other Protective Tools
The MP monitoring complements other lung protection features on the SV 300, such as:
Driving Pressure and Plateau Pressure limits
Transpulmonary Pressure guidance for personalized PEEP titration
Recruitment Maneuvers to re-expand collapsed lung tissue
C20/C and PV tools to assess lung compliance and overinflation
This multi-parameter approach enables a holistic lung protection strategy, helping to prevent volutrauma, barotrauma, and atelectrauma.
Conclusion
The Mindray SV 300 ventilator empowers clinicians to move beyond traditional parameters by incorporating Mechanical Power into everyday decision-making. This facilitates proactive, individualized ventilation strategies that enhance patient safety, improve outcomes, and uphold the principles of lung-protective ventilation in both ICU and perioperative settings.
For any machine inquiry or clinical training support
Contact: 0923798904
18/12/2025
Mechanical Ventilator
Brand: Mindray
Model: SV-300
Patient Support: Adult, pediatric, neonatal
Contact
0923798904
St. Peter General Specialized Hospital - ቅዱስ ጴጥሮስ አጠቃላይ ስፔሻላይዝድ ሆስፒታልLandmark General Hospital A.AHallelujah General HospitalDire Godana HospitalMuse General Hospital AdamaHospitaala Kompireensiivii Ispeeshaalaayizdii Yuunivarsiitii WallaggaaOromia Physicians Association - Waldaa Haakimoota OromiyaaUniversity of Gondar Teaching and Referral HospitalFelege Hiwot Referral HospitalHiwot Fana specialized university hospital drug information center