A Division of CYSA Development. Washington D.C. - Boston - New York - Jeddah - Dubai U.S. We are the only product in the world that holds this designation.
Smoke and Fire is the exclusive value-added distributor for BLE Smoke and Fire Curtain gravity fail-safe fire protective smoke curtains in North America. In the United States, we are the leader in fire protective smoke curtain technology, which allows for more open space and natural light (providing LEED credit) in a building while protecting its occupants for safe evacuation by keeping the smoke
layer six feet above the finished floor during a fire condition. Our automatic fire protective smoke barriers and partitions allow for open corridors in the atrium and are utilized for area separation. We create smoke datums with our technology under NFPA 92B guidelines in conjunction with smoke control to reduce extraction and make up air requirements. In our projects over-seas, our associates use less smoke extraction, and use more curtain systems to create more datums. We are UL listed under UL 10D Fire Protective Curtains which UL established for our product. We currently hold a UL S label for UL 1784 and a UL oversize report AND UL 864 for our group control panels. We have installed at The Kennedy Center for the Performing Arts, Federal Housing Finance Agency, UNC Dental School, MIT Neural and Cognitive Sciences Building, UMASS Integrated Sciences Building, PRINCETON Chemistry Building, FIU School for International and Public Affairs, Max Planck Institute (Florida), PNC Place in Washington, DC among many others and are currently installing at the Smithsonian National Museum of Natural History, as well as several Ground Zero and government installations. Smoke Curtain Features:
■ Smoke and Fire Protection in One Solution: UL Listed opening protective for 1 or 2 hour fire rating
■UL 10B, 10D, UL S Label
■Advanced & Mature Technology
■Controlled Descent
■Lightweight, easy to lift by hand
■Installs Compactly Overhead - as little as 6” of ceiling headroom
■Design freedom, LEED Credit
■Available in Sizes up to 90 feet wide x 42 feet high
■Low Life Cycle Cost
■Fail Safe Design
■Battery Back-up standard, NOT Required for Gravity Fail Safe Deployment
Full service CAD enabled design development, construction document review, shop drawings, verify in field shop drawings, full service installation, and coordination curtain system with fire alarm, electrical and air extraction companies, commissioning, smoke bomb testing and acceptance testing per strict adherence to NFPA 80 guidelines with the authority having jurisdiction.